Solvent Based Coal Tar Cleaner

Services

Solvent Based Coal Tar Cleaner containing highly concentrated aromatic hydrocarbons and surfactants.

Product Name: UNITEDCHEM-CTR

USAGE AREA

It is used to clean coal tar, coal dust, asphalt, gas oil, crude oil and petroleum derivative loads in tanks and warehouses. It does not leave any carbon residue on the cleaned surface. Because of its rapid emulsification properties, the amount of wastewater is minimized. It is suitable for use with sea water.

USAGE METHOD

Prior to cleaning with UNITEDCHEM-CTR, prewash with water at 60-80°C should be applied for two hours. Pre-rinse with cold water in crude oil and gas oil cleaning.

NOTE: Pollution and cargo wastes that can be mechanically removed manually before cleaning should be removed.

1 – CIRCULATION METHOD

After pre-washing and mechanical cleaning is complete, a UNITEDCHEM-CTR solution with a rate of 8-10% is prepared. It is recommended to bring the solution temperature to 60-80°C. When preparing the amount of solution, it is necessary to have a sufficient volume of solution to circulate the circulation pump. Circulation is carried out for 6-8 hours and the solution can be transferred to other tanks. Depending on the condition of the tanks to be cleaned, 3 tanks are cleaned with the same solution. Rinsing with fresh water or sea water should be done in tanks after cleaning. Steam heating should be applied to remove the tanks from chloride.

2 – SPOT CLEANING

Spraying, brushing and spraying methods can be applied in spot cleaning. UNITEDCHEM-CTR is expected to react on the surface for 20-30 minutes after application to the surface and rinsing with plenty of water.

3 – LOCKER CLEANING

1/1-1/3 is heated to 50-60°C. It is applied to the surface by spraying method or brushing method. It is expected to react for 30 minutes. Rinse with sea water or fresh water after cleaning.

TYPICAL PHYSICAL CHARACTERISTICS

Solubility:  Completely  Water-Soluble
Storage Temperature:  -5 and 30 °C
Water Dilution Rate:  % 8-10 , 1/1-1/3
Chemical Material Storage: Storage period is 3 years

The above mentioned statements are standard cleaning procedures and they may vary based on the physical condition of tanks, lockers and load types.

Click to Chemical Products page to see our all chemical products.